1. In this Schedule, unless the context otherwise requires —| “Adjusted Volume” or “Vadj” means adjusted volume as defined in Part 2 of the Fourth Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; |
| “Annual Energy Consumption” or “AEC” means the amount of energy consumed over 8,760 hours expressed in kilowatt‑hour as specified in the test report; |
| “Ballast Efficiency”, in relation to a ballast, means the ratio of Plamp to Pinput (the input power of the lamp-ballast circuit) with possible sensors, network connections and other auxiliary loads disconnected as specified in the test report, expressed in percentage; [S 730/2019 wef 01/11/2019] |
| “casement or window type air‑conditioner” has the same meaning as in Part 2 of the First Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; |
| “chilled”, in relation to a commercial storage refrigerator, means that the storage temperature of foodstuffs in the refrigerator is continuously maintained at a temperature at or above –1°C and at or below 5°C; [S 113/2025 wef 01/04/2025] |
| “CIE” means the International Commission on Illumination; |
| “Coefficient of Performance” or “COP” means the ratio of the total cooling capacity expressed in Watts to the total effective input power expressed in Watts, as specified in the test report; |
| “commercial storage refrigerator” has the meaning given by Part 2 of the Fourth Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; [S 113/2025 wef 01/04/2025] |
| “compact fluorescent lamp with integrated ballast” or “CFLi” has the same meaning as in Part 2 of the Third Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; |
| “compact fluorescent lamp without integrated ballast” or “CFLni” has the same meaning as in Part 2 of the Third Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; [S 730/2019 wef 01/11/2019] |
| “counter”, in relation to a commercial storage refrigerator, means that the refrigerator is lower than 1,050 mm in height with one or more doors or drawers accessing the same compartment; [S 113/2025 wef 01/04/2025] |
| “covered CFLi” means a CFLi with an outer lamp envelope; |
| “EEI Class B1”, in relation to a non-high frequency ballast, means the minimum Ballast Efficiency required for the ballast to be rated as Class B1 under Table 17 of Commission Regulation (EC) No. 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of the Council; [S 730/2019 wef 01/11/2019] |
| “Energy Consumption” or “EC”, in relation to a clothes dryer, means the amount of energy consumed per cycle expressed in kilowatt‑hour as specified in the test report; |
| “Energy Efficiency Index” or “EEI”, in relation to a commercial storage refrigerator, means the number determined in accordance with the following formula: [S 113/2025 wef 01/04/2025] |
| “frozen”, in relation to a commercial storage refrigerator, means that the storage temperature of foodstuffs in the refrigerator is continuously maintained at a temperature at or below –15°C; [S 113/2025 wef 01/04/2025] |
| “incandescent lamp” has the same meaning as in Part 2 of the Third Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; |
| “IEC” means the International Electrotechnical Commission; |
| “IEEE” means the Institute of Electrical and Electronics Engineers; [S 603/2018 wef 01/10/2018] |
“Integrated Energy Efficiency Ratio” or “IEER” means the number determined in accordance with the following formula:| (0.020 × A) + (0.617 × B) + (0.238 × C) + (0.125 ×D), |
| | | (a) | A is COP at full load cooling capacity; |
|
| | (b) | B is COP at 75% part load cooling capacity; |
|
| | (c) | C is COP at 50% part load cooling capacity; and |
|
| | (d) | D is COP at 25% part load cooling capacity; |
|
|
|
[S 199/2021 wef 01/04/2021] |
| “International Energy Efficiency class” or “IE”, in relation to a motor, has the same meaning as in IEC 60034-30-1 (2014); [S 603/2018 wef 01/10/2018] |
| “ISO” means the International Organization for Standardization; |
| “Lamp Efficacy” or “ηlamp” means the ratio of the rated luminous flux, expressed in lumens, ϕ, to the rated Plamp, expressed in Watts; [S 730/2019 wef 01/11/2019] |
“Lamp Power Consumption” or “Plamp” means —| (a) | for a covered CFLi, Pcovered CFLi × 0.95; and | | (b) | for any other lamp, the rated power consumed by the lamp, excluding power dissipated by non‑integrated auxiliary equipment, such as ballasts, transformers or power supplies, expressed in Watts, as specified in the test report; |
|
| “LED lamp” has the same meaning as in Part 2 of the Third Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; |
| “linear LED lamp” has the same meaning as in Part 2 of the Third Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; [S 711/2023 wef 01/04/2024] |
| “linear, double-capped fluorescent lamp without integrated ballast” or “LFL” has the same meaning as in Part 2 of the Third Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; [S 730/2019 wef 01/11/2019] |
| “ϕ” means the rated luminous flux of a lamp expressed in lumens, as specified in the test report; |
“Minimum Nominal Efficiency” means the number determined in accordance with the following formula:| (a) | A is 0.3569 for a 2-pole motor, 0.0773 for a 4-pole motor and 0.1252 for a 6-pole motor; | | (b) | B is -3.3076 for a 2-pole motor, -1.8951 for a 4-pole motor and -2.613 for a 6-pole motor; | | (c) | C is 11.6108 for a 2-pole motor, 9.2984 for a 4-pole motor and 11.9963 for a 6-pole motor; | | (d) | D is 82.2503 for a 2-pole motor, 83.7025 for a 4-pole motor and 80.4769 for a 6-pole motor; and | | (e) | P is the rated power output of the motor; [S 603/2018 wef 01/10/2018] |
|
| “N”, in relation to a split type air‑conditioner, means the total number of mountings which are assembled to form a matched functional unit; |
| “net volume”, in relation to a commercial storage refrigerator, means the volume containing foodstuffs within the load limit of the refrigerator; [S 113/2025 wef 01/04/2025] |
| “Nominal Efficiency” or “ƞN”, in relation to a motor, means the ratio of mechanical output power to the electrical input power, expressed in percentage, as specified in the test report, and at rated voltage and frequency; [S 603/2018 wef 01/10/2018] |
| “On-Mode Power Consumption” or “P”, in relation to a television, means the power consumed when the television produces sound and picture, expressed in Watts, as specified in the test report; |
| “Pcovered CFLi” means rated power consumed by a covered CFLi, excluding power dissipated by non‑integrated auxiliary equipment, such as ballasts, transformers or power supplies, expressed in Watts, as specified in the test report; |
| “passive standby power”, in relation to a television, means the power consumed when the television is in passive standby mode, expressed in Watts, as specified in the test report; [S 711/2023 wef 01/04/2024] |
| “screen area”, in relation to a television, means the area of the television screen expressed in square decimetres as specified in the test report; |
| “single‑phase portable unitary single duct air‑conditioner” or “PAC” has the same meaning as in Part 2 of the First Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; [S 711/2023 wef 01/04/2024] |
| “split type (inverter) air‑conditioner” has the same meaning as in Part 2 of the First Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; |
| “split type (non‑inverter) air‑conditioner” has the same meaning as in Part 2 of the First Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; |
| “SS” means the Singapore Standards; [S 113/2025 wef 01/04/2025] |
“Standard Annual Energy Consumption” or “SAEC” means the standard annual energy consumption in kWh/year determined in accordance with the following formula:| (a) | Vn is the net volume, which is the sum of the net volumes of all compartments of the refrigerator, expressed in litres; | | (b) | if the refrigerator is a vertical chilled type refrigerator — A is 1.643 and B is 609; | | (c) | if the refrigerator is a vertical frozen type refrigerator — A is 4.928 and B is 1472; | | (d) | if the refrigerator is a counter chilled type refrigerator — A is 2.555 and B is 1790; and | | (e) | if the refrigerator is a counter frozen type refrigerator — A is 5.840 and B is 2380; |
[S 113/2025 wef 01/04/2025] |
“standby mode” means a condition where the good is connected to the mains power source and consumes energy to do the following only:| (a) | allowing the activation of any other mode; | | (b) | displaying information, including time; | | (c) | indicating the status of the good; | | (d) | continuously regulating or monitoring internal components of the good, based on information collected by sensors; | | (e) | heating the crankcase; |
|
| “standby power” means the power consumed when the good is in standby mode, expressed in Watts, as specified in the test report; |
| “three-phase variable refrigerant flow (VRF) air-conditioner” has the meaning given by Part 2 of the First Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; [S 199/2021 wef 01/04/2021] |
| “tungsten filament lamp” means an incandescent lamp that has a filament made of tungsten and is operated in an evacuated bulb or surrounded by inert gas; |
| “tungsten halogen lamp” means an incandescent lamp that has a filament made of tungsten and is surrounded by gas containing halogens or halogen compounds; |
| “Uniform Energy Factor” or “UEF”, in relation to a water heater, means the measure of the overall efficiency of the water heater, as specified in the test report; [S 113/2025 wef 01/04/2025] |
| “vertical”, in relation to a commercial storage refrigerator, means that the refrigerator is equal to or higher than 1,050 mm in height with one or more doors or drawers accessing the same compartment; [S 113/2025 wef 01/04/2025] |
| “water heater” has the meaning given by Part 2 of the Eighth Schedule to the Energy Conservation (Prescribed Regulated Goods) Order 2017; [S 113/2025 wef 01/04/2025] |
| “Weighted COP” means the sum of 0.4 × COP at full load cooling capacity and 0.6 × COP at part load cooling capacity. |
|